luminaires were enough after the calculation in the Cargo-partner offices in Bratislava
LED panels in the MAX tool shop – and it feels brighter
luminaires designed in DIALux for more than 40,000 m² in Partizánske
successful projects in 16 years
What we assess in a lighting design
A good design starts with questions, not with a catalogue. We choose luminaires according to what happens in the space, the environment they will work in and what they will cost to run – not according to what was installed there before.
Activities and visual tasks
Assembly, storage, offices and shops each need different illuminance levels. The required values are set by the standard according to the activity, not by feel.
Environment
Dust, humidity, frost, chemicals or an explosive atmosphere determine the protection rating (IP), impact resistance (IK) and whether an Ex-certified luminaire is needed.
Glare and uniformity
Light must not dazzle or leave dark spots. In the calculation we check the UGR glare rating and the uniformity of illuminance at workplaces.
Light colour and colour rendering
We choose the colour temperature and the colour rendering index Ra according to the task – quality inspection needs different light from a racking aisle.
Consumption and payback
We compare the luminous efficacy of luminaires, operating hours and control options. You get the savings and the payback period in figures.
Installation and maintenance
Mounting method, ceiling height and access to the luminaires – so that the lighting works for years without service calls or tube replacements.
Not sure where to start? We can advise even without drawings – just describe the space and what bothers you about the lighting.
Which standards we design to
For each type of space, the standard sets its own requirements for minimum illuminance, uniformity and the glare limit. The DIALux calculation shows whether the design meets the standard before any luminaires are bought – not after installation.
Specific values for halls, warehouses, offices, shops and sports pitches can be found on our solutions by space pages.
| STANDARD | TYPE OF SPACE |
|---|---|
| EN 12464-1 | indoor workplaces – halls, warehouses, offices, shops, schools |
| EN 12464-2 | outdoor workplaces – sites, loading ramps, car parks |
| EN 13201 | roads, footpaths and public spaces |
| EN 12193 | sports facilities – pitches and sports halls |
| EN 1838 | emergency lighting of escape routes |
What you get and what we need from you
What you get
A lighting calculation in DIALux evo
- illuminance and uniformity for each zone
- UGR glare assessment at workplaces
- number and layout of luminaires on the floor plan
- a 3D visualisation of the space
- a list of the proposed luminaires
- consumption, savings and payback
Sample DIALux calculation: illuminance distribution across an outdoor site. How to read the calculation is explained in a blog article.
What we need from you
Documents – depending on what you have
New space or project: floor plan and section (ideally DWG or DXF), ceiling height and construction, use of the rooms.
Refurbishment: photos of the existing lighting, number and type of luminaires, operating hours; if available, also the electrical installation design and the verification report.
Emergency lighting: the fire safety design with escape routes and the technical report that specifies where emergency lighting is required.
Don’t have any of these? We will carry out a site survey, measure the space and build the model ourselves.
Case study · offices
Cargo-partner: after the calculation, fewer than half the luminaires were enough
The most common mistake in a modernisation is one-for-one replacement. The offices of the logistics company Cargo-partner in Bratislava were lit by 172 recessed luminaires with fluorescent tubes, each drawing about 100 W. After the calculation they were replaced by 74 LED panels 60 × 60 cm rated at 54 W – the installed load fell from 17.2 kW to 4 kW.
Before
- 172 recessed luminaires with fluorescent tubes
- about 100 W per luminaire
Solution
- 74 LED panels 60 × 60 cm, 54 W
- layout based on the lighting calculation
- 10 years without a service call
“After 10 years everything works and we haven’t changed anything so far.”
Miroslav Šulovský, Manager Logistics, cargo-partner SR, s.r.o.
Cargo-partner offices, Bratislava
luminaires
reduction in installed load
instead of about 100 W per luminaire
without any work on the lighting
How the design process works
Brief
Tell us what you need to light, how you use the space and what bothers you about the current lighting.
Site survey or documents
We visit and measure the space – or drawings and photos are enough.
DIALux calculation
The simulation determines the type, number and layout of luminaires according to the standard. For most projects it is free of charge.
Quote with payback
Price, savings and payback in one document.
Supply and installation
We supply the luminaires, install them and set up the controls.
Designs already in operation
All references →
Production and warehouses, Partizánske1,798 luminaires · > 40,000 m² · 72 % savingsLayout, number and wattage of the luminaires for each hall designed in DIALux. DALI controls saved a further 30 %.
Wertheim, Dunajská Streda961 luminaires with DALI · 80 % savings · 1.6-year payback400 W discharge lamps were replaced by high-efficiency PRIMUS luminaires with emergency modules and programmed lighting scenes.
Production and warehouses, Dolné Vestenice742 luminaires · 12,000 m² · 60 % savingsDischarge lamps at the end of their life were replaced by LED luminaires, parts of the halls are switched by motion sensors and DALI dims the lighting according to daylight.
Frequently asked questions
Answers to the questions customers ask us most often about lighting design.
Is it enough to replace old luminaires one for one?
Often not. With one-for-one replacement, the new lighting tends to be oversized or uneven. In the Cargo-partner offices, the calculation showed that 74 LED panels would replace 172 luminaires; in the MAX shop, 16 panels were enough instead of 34.
Do you need to visit the site?
Not always. For a new space, a floor plan, a section and the ceiling height are often enough. For a refurbishment we recommend a site survey – we check the condition of the luminaires, the wiring and the switchboards and measure the space.
How much does a lighting design cost?
For most projects the lighting calculation is free of charge. For more complex projects we charge for it – if you then carry out the project with our luminaires, we can credit up to 50 % of the amount paid.
How long does the design take?
It depends on the scope and completeness of the documents – one hall is a different task from a whole site. We will give you a date as soon as we receive the brief.
Which standards do you design to?
Interiors to EN 12464-1, outdoor workplaces to EN 12464-2, roads to EN 13201, sports facilities to EN 12193 and emergency lighting to EN 1838.
Do you also design emergency lighting?
Yes, to EN 1838. For this we need the fire safety design with escape routes and the technical report specifying which areas require emergency lighting.
We have a design with specific luminaires. Can you assess it?
Yes. We will propose an equivalent replacement from our range and compare its parameters with the design – luminous flux, power, optics and protection rating.
Can you also help with lighting controls?
Yes. At the design stage we already determine where daylight dimming, presence sensors or lighting scenes make sense. More about control design and programming.
Read on our blog
All articles →Related services
Solutions by type of space