Get Quote

Have a question? Leave us a message.

9. July 2023

Parks

Lighting for parks, town squares and memorials

A park is not about as much light as possible. People should feel safe on the paths and benches, the trees, memorials and fountains should stand out – and the rest of the park should stay dark for the wildlife living in it.

For municipalities, towns and site managers we design, supply and install LED lighting for parks, footpaths, squares and memorial sites – with warm light, no light spilling towards the sky and dimming in the late hours.

See the case study
The SNP memorial at Jankov vŕšok with LED park luminaires – a FREYALED project
21

LED park luminaires at the Jankov vŕšok memorial site – with a pre-programmed dimming curve

3,000 K

warm white – pleasant light for parks that disturbs the surroundings less

1,550+

successful lighting projects over 16 years

5 years

warranty on street lighting luminaires

What park lighting has to do

A park, a town square and a memorial are places where people spend time, not just pass through. The lighting should be safe and pleasant at the same time – and it must not turn the park into an island of light that disturbs the residents of nearby houses and the natural world.

Safe footpaths

Even light on paths, steps and around benches, so that both the ground and people coming the other way are clearly visible. No dark stretches between luminaires.

Atmosphere and architecture

Warm white and decorative luminaires that suit both a park and a historic town centre. We pick out memorials and trees with accent lighting.

Respect for nature

Luminaires with no upward light, warmer colours and amber NICOLE Bat light in places where bats are present.

Less light at night

After midnight a fraction of the light is enough. Dimming and motion sensors save energy, and the park stays dark at night when nobody is there.

How much light a park needs

Footpaths, parks and squares fall under EN 13201 into the P classes, which set the average and minimum illuminance of the area. The designer chooses the class according to how many people use the park in the evening and what the surroundings are like.

The table shows a selection of classes with their typical use. We determine the exact values and the layout of luminaires for your park in a lighting calculation.

CLASSAVERAGE / MINIMUM AND TYPICAL USE
P210 / 2 lx – town squares, pedestrian zones, busy parks in the centre
P3 – P47.5 / 1.5 lx down to 5 / 1 lx – urban parks and footpaths
P5 – P63 / 0.6 lx down to 2 / 0.4 lx – little-used footpaths, park edges, woodland parks

Luminaires for parks and town squares

In a park we combine lower luminaires along the paths with decorative lanterns on the main routes and the square. For places with no cable we use solar luminaires.

See the full street lighting range →
URBAN II LED street lighting

Squares and main routes

Decorative and park lights

URBAN II in the shape of a traditional lantern with LED, 34 to 66 W and low glare. STELA MINI and SILVA ECO for lower poles along the main paths, with adjustable tilt and dimming.

BRUTO LED street lighting

Footpaths, steps, entrances

Bollards with a sensor

BRUTO at a height of 47.5 or 97.5 cm lights the path without glare. Built-in motion sensor, adjustable output and colour temperature, pole or wall mounting.

NICOLE Bat LED street lighting

Natural sites and places with no cable

Wildlife-friendly luminaires

NICOLE Bat with amber light and no UV radiation for places where bats are present. For remote paths, shelters and viewpoints with no cable, the solar SOLAR FLEXI and SOLAR with a motion sensor.

LED street lighting on a footpath and in the town centre of Gbely

Controls: the park is lit when people are in it

In the evening the park is alive, after midnight it is empty. Lighting controls reduce the output according to a pre-programmed night curve, sensors bring the path up to full brightness only when there is movement, and a photocell switches the lighting on exactly at dusk.

  • autonomous dimming – a night curve with no extra cabling
  • motion sensors in the BRUTO bollards
  • photocell or astronomical time switch
  • a separate circuit for accent lighting of memorials and trees
  • decorative accent lighting switched off after midnight
  • solar luminaires with a sensor where there is no cable
More about control design and programming →

Case study

The SNP memorial at Jankov vŕšok

Together with Slovex Alfa we lit the grounds of the SNP memorial at Jankov vŕšok. We used 21 LED park luminaires with a power input of 14 W and a colour temperature of 3,000 K. The aim was to bring out the architecture of the memorial and light the paths evenly, without needless light pollution. Thanks to a pre-programmed dimming curve, the lighting adapts to conditions through the night and saves energy.

Brief

  • a memorial site with terraces and paths
  • bring out the architecture
  • no light pollution

Solution

  • 21 LED park luminaires of 14 W
  • warm white 3,000 K
  • dimming curve through the night
The grounds of the memorial at Jankov vŕšok with LED park luminaires
21

park luminaires

14 W

power input per luminaire

3,000 K

colour temperature

294 W

power input of the lighting across the whole site

How we work

01

Site survey

We walk the park after dark – the paths, benches, memorials, trees and the places that are dark today.

02

Design and calculation

Lighting class, type and height of luminaires, colour temperature and accent lighting of landmarks, all in a DIALux calculation.

03

Quotation

Luminaires, poles, controls and installation in a single quotation, with an energy consumption calculation.

04

Installation

In phases, so the park stays open. We keep trenching to a minimum by using solar luminaires wherever that makes sense.

05

Warranty and service

A 5-year warranty on street lighting luminaires, plus servicing and spare parts.

More projects in towns and villages

All street lighting projects →

FAQ

What municipalities and park managers ask us most often.

How much light does a park need?

Footpaths and parks fall under EN 13201 into the P classes. An urban park with people about in the evening is typically class P3 or P4 (an average of 7.5 or 5 lx), squares and pedestrian zones P2 (10 lx), and little-used park edges P5 to P6. We determine the class and the layout of luminaires in a calculation.

Which colour temperature should we choose for a park?

For parks and residential areas we recommend warm white 3,000 K – it is more pleasant and disturbs both the surroundings and wildlife less. Where bats are present, amber NICOLE Bat luminaires with no UV radiation.

Can a footpath be lit without trenching?

Yes, with SOLAR FLEXI or SOLAR solar luminaires with a battery and a motion sensor. They suit remote paths, shelters and viewpoints where there is no street lighting cable.

How can light pollution be reduced?

With luminaires that emit no light above the horizontal, the right tilt, a warmer light colour and dimming at night. We put the accent lighting of memorials and trees on a separate circuit that switches off after midnight.

Do you also supply decorative luminaires for a historic town centre?

Yes – URBAN II combines the traditional lantern shape with LED technology and suits squares and pedestrian zones. Where the design requirements are specific, we will propose a bespoke solution.

What warranty do you provide?

5 years on street lighting luminaires. The service life of LED luminaires is 100,000 hours.

From our blog

All articles →

Related solutions

We will develop a tailor-made solution for you

We price each project according to the needs of your space. Let our specialists prepare a price calculation for you.

Michal Chochlík

commercial and technical representative
(+421) 904 404 016
(+421) 32 286 14 84
led@freyaled.com