Lighting for parks, town squares and memorials
A park is not about as much light as possible. People should feel safe on the paths and benches, the trees, memorials and fountains should stand out – and the rest of the park should stay dark for the wildlife living in it.
For municipalities, towns and site managers we design, supply and install LED lighting for parks, footpaths, squares and memorial sites – with warm light, no light spilling towards the sky and dimming in the late hours.
LED park luminaires at the Jankov vŕšok memorial site – with a pre-programmed dimming curve
warm white – pleasant light for parks that disturbs the surroundings less
successful lighting projects over 16 years
warranty on street lighting luminaires
What park lighting has to do
A park, a town square and a memorial are places where people spend time, not just pass through. The lighting should be safe and pleasant at the same time – and it must not turn the park into an island of light that disturbs the residents of nearby houses and the natural world.
Safe footpaths
Even light on paths, steps and around benches, so that both the ground and people coming the other way are clearly visible. No dark stretches between luminaires.
Atmosphere and architecture
Warm white and decorative luminaires that suit both a park and a historic town centre. We pick out memorials and trees with accent lighting.
Respect for nature
Luminaires with no upward light, warmer colours and amber NICOLE Bat light in places where bats are present.
Less light at night
After midnight a fraction of the light is enough. Dimming and motion sensors save energy, and the park stays dark at night when nobody is there.
How much light a park needs
Footpaths, parks and squares fall under EN 13201 into the P classes, which set the average and minimum illuminance of the area. The designer chooses the class according to how many people use the park in the evening and what the surroundings are like.
The table shows a selection of classes with their typical use. We determine the exact values and the layout of luminaires for your park in a lighting calculation.
| CLASS | AVERAGE / MINIMUM AND TYPICAL USE |
|---|---|
| P2 | 10 / 2 lx – town squares, pedestrian zones, busy parks in the centre |
| P3 – P4 | 7.5 / 1.5 lx down to 5 / 1 lx – urban parks and footpaths |
| P5 – P6 | 3 / 0.6 lx down to 2 / 0.4 lx – little-used footpaths, park edges, woodland parks |
Luminaires for parks and town squares
In a park we combine lower luminaires along the paths with decorative lanterns on the main routes and the square. For places with no cable we use solar luminaires.

Squares and main routes
Decorative and park lights
URBAN II in the shape of a traditional lantern with LED, 34 to 66 W and low glare. STELA MINI and SILVA ECO for lower poles along the main paths, with adjustable tilt and dimming.

Footpaths, steps, entrances
Bollards with a sensor
BRUTO at a height of 47.5 or 97.5 cm lights the path without glare. Built-in motion sensor, adjustable output and colour temperature, pole or wall mounting.
Controls: the park is lit when people are in it
In the evening the park is alive, after midnight it is empty. Lighting controls reduce the output according to a pre-programmed night curve, sensors bring the path up to full brightness only when there is movement, and a photocell switches the lighting on exactly at dusk.
- autonomous dimming – a night curve with no extra cabling
- motion sensors in the BRUTO bollards
- photocell or astronomical time switch
- a separate circuit for accent lighting of memorials and trees
- decorative accent lighting switched off after midnight
- solar luminaires with a sensor where there is no cable
Case study
The SNP memorial at Jankov vŕšok
Together with Slovex Alfa we lit the grounds of the SNP memorial at Jankov vŕšok. We used 21 LED park luminaires with a power input of 14 W and a colour temperature of 3,000 K. The aim was to bring out the architecture of the memorial and light the paths evenly, without needless light pollution. Thanks to a pre-programmed dimming curve, the lighting adapts to conditions through the night and saves energy.
Brief
- a memorial site with terraces and paths
- bring out the architecture
- no light pollution
Solution
- 21 LED park luminaires of 14 W
- warm white 3,000 K
- dimming curve through the night
park luminaires
power input per luminaire
colour temperature
power input of the lighting across the whole site
How we work
Site survey
We walk the park after dark – the paths, benches, memorials, trees and the places that are dark today.
Design and calculation
Lighting class, type and height of luminaires, colour temperature and accent lighting of landmarks, all in a DIALux calculation.
Quotation
Luminaires, poles, controls and installation in a single quotation, with an energy consumption calculation.
Installation
In phases, so the park stays open. We keep trenching to a minimum by using solar luminaires wherever that makes sense.
Warranty and service
A 5-year warranty on street lighting luminaires, plus servicing and spare parts.
More projects in towns and villages
All street lighting projects →FAQ
What municipalities and park managers ask us most often.
How much light does a park need?
Footpaths and parks fall under EN 13201 into the P classes. An urban park with people about in the evening is typically class P3 or P4 (an average of 7.5 or 5 lx), squares and pedestrian zones P2 (10 lx), and little-used park edges P5 to P6. We determine the class and the layout of luminaires in a calculation.
Which colour temperature should we choose for a park?
For parks and residential areas we recommend warm white 3,000 K – it is more pleasant and disturbs both the surroundings and wildlife less. Where bats are present, amber NICOLE Bat luminaires with no UV radiation.
Can a footpath be lit without trenching?
Yes, with SOLAR FLEXI or SOLAR solar luminaires with a battery and a motion sensor. They suit remote paths, shelters and viewpoints where there is no street lighting cable.
How can light pollution be reduced?
With luminaires that emit no light above the horizontal, the right tilt, a warmer light colour and dimming at night. We put the accent lighting of memorials and trees on a separate circuit that switches off after midnight.
Do you also supply decorative luminaires for a historic town centre?
Yes – URBAN II combines the traditional lantern shape with LED technology and suits squares and pedestrian zones. Where the design requirements are specific, we will propose a bespoke solution.
What warranty do you provide?
5 years on street lighting luminaires. The service life of LED luminaires is 100,000 hours.